[Paper]Comparison of Clinical and Biomechanical Outcomes of Small Incision Lenticule Extraction With 120μm and 140μm Cap Thickness
2022.02.07
1026
Comparison of Clinical and Biomechanical Outcomes of Small Incision Lenticule Extraction With 120μm and 140μm Cap Thickness
TVST July 2021 Vol: 10, Issue 8
Author-EYEREUM EYE CLINIC with YONSEI UNIVERSITY COLLEGE OF
MEDICINE
The purpose of this study was to compare the clinical outcomes and corneal biomechanical changes between 120-µm and 140-µm cap thickness after small incision lenticule extraction (SMILE).
The conclusion of this research is SMILE with 120-µm and 140-µm cap thickness provided excellent predictable outcomes according to our enhanced correction nomogram.